Abstract:
This paper presents a study, which describes the influence of the dynamic behaviour of the intake tower on the experimental results obtained from operational modal analysis of Cabril dam. A 3D finite element model, for the intake tower of Cabril dam, was developed in order to study the dynamic behaviour of this neighbour structure of the dam. The main dynamic parameters computed and evaluated experimentally for this structure are summarized and discussed, to understand how they can interfere in the modal identification of Cabril dam.