DSpace Repository

IPaintS - Intelligent Coatings for Concrete Structures: immobilization of pH indicators on coating membranes

Show simple item record

dc.contributor.author Cristino, A. pt_BR
dc.contributor.author Lopreto, J. pt_BR
dc.contributor.author Silva, H. M. pt_BR
dc.contributor.author Santos Silva, A. pt_BR
dc.contributor.author Rodrigues, M. P. pt_BR
dc.contributor.author Cabral-Fonseca, S. pt_BR
dc.contributor.author Ferreira, O. pt_BR
dc.contributor.author Nunes, J. pt_BR
dc.contributor.author Soeira, B. pt_BR
dc.contributor.author Galhano, R. pt_BR
dc.contributor.editor Grantham, M. pt_BR
dc.contributor.editor Custódio, J. pt_BR
dc.contributor.editor Real, S. pt_BR
dc.date.accessioned 2026-02-02T10:49:49Z pt_BR
dc.date.accessioned 2026-05-05T16:31:42Z
dc.date.available 2026-02-02T10:49:49Z pt_BR
dc.date.available 2026-05-05T16:31:42Z
dc.date.issued 2025-06-13 pt_BR
dc.identifier.citation https://doi.org/10.1051/matecconf/202540914002 pt_BR
dc.identifier.uri http://dspace2.lnec.pt:8080/jspui/handle/123456789/1019523 pt_BR
dc.identifier.uri http://repositorio.lnec.pt:8080/jspui/handle/123456789/1019523
dc.description.abstract In Portugal and over the world, a significant number of concrete structures face challenges due to expansive chemical reactions, such as the alkali-silica reaction (ASR). These reactions have been shown to cause various types of damage, with microcracking being the most common, resulting from internal stresses created by the expansion of reaction products. It is well-documented that, over time, these microcracks can develop into significant fissures due to the hygroscopic nature of these products, which accelerates concrete degradation and potentially compromises structural integrity. One key aspect of ASR products is the presence of alkaline hydroxides in the gel formation process, resulting in elevated pH levels. When this gel reaches the concrete carbonated surface, a change in pH occurs. Based on this premises, the project IPaintS was undertaken to develop a coating that could detect the formation of ASR products on concrete surfaces by identifying variations in pH. This paper presents the results of the preliminary tests conducted, specifically the tests performed to confirm the possibility of immobilising pH indicators in a coating membrane and assess performance characteristics of the functionalised coating. Results show the effective immobilization of a pH indicator on a coating membrane without the loss of some fundamental properties of both the indicator and the coating membrane. pt_BR
dc.language.iso eng pt_BR
dc.publisher EDP Sciences pt_BR
dc.relation IPaintS - Intelligent Coating Sensors for Treating Concrete Structures (LISBOA-01-0247-FEDER-047141) pt_BR
dc.rights openAccess pt_BR
dc.subject coatings pt_BR
dc.subject concrete pt_BR
dc.subject alkali-silica reaction pt_BR
dc.subject pH pt_BR
dc.title IPaintS - Intelligent Coatings for Concrete Structures: immobilization of pH indicators on coating membranes pt_BR
dc.type conferenceObject pt_BR
dc.description.pages 6p. pt_BR
dc.description.comments This work was supported by SIKA PORTUGAL and funded through POR Lisboa – Lisbon Regional Operational Program (Portugal2020), under the project "IPaintS - Intelligent Coating Sensors for Treating Concrete Structures” (LISBOA-01-0247-FEDER-047141). The authors also acknowledge the Centro de Recursos Naturais e Ambiente (CERENA), a research unit funded by FCT through project UIDB/04028/2020. pt_BR
dc.identifier.local LNEC, Lisboa pt_BR
dc.description.volume Volume 409 (2025) pt_BR
dc.description.sector DM/NMOMM pt_BR
dc.description.magazine MATEC Web of Conferences pt_BR
dc.identifier.conftitle Concrete Solutions 2025 – 9th International Conference on Concrete Repair, Durability & Technology pt_BR
dc.contributor.peer-reviewed SIM pt_BR
dc.contributor.academicresearchers SIM pt_BR
dc.contributor.arquivo NAO pt_BR


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account