| dc.contributor.author |
Losanno, D.
|
pt_BR |
| dc.contributor.author |
Prakash, S.
|
pt_BR |
| dc.contributor.author |
Medaglia, P.
|
pt_BR |
| dc.contributor.author |
Parisi, F.
|
pt_BR |
| dc.contributor.author |
Konstantinidis, D.
|
pt_BR |
| dc.contributor.author |
Tubaldi, E.
|
pt_BR |
| dc.contributor.author |
Ahmadi, H.
|
pt_BR |
| dc.contributor.author |
Strauss, A.
|
pt_BR |
| dc.contributor.author |
De Domenico, D.
|
pt_BR |
| dc.contributor.author |
Vamvatsikos, D.
|
pt_BR |
| dc.contributor.author |
Lachanas, C.
|
pt_BR |
| dc.contributor.author |
Vassiliou, M.
|
pt_BR |
| dc.contributor.author |
Ribeiro, F.
|
pt_BR |
| dc.contributor.author |
Correia, A.A.
|
pt_BR |
| dc.contributor.editor |
Gerard J. O’Reilly |
pt_BR |
| dc.contributor.editor |
Gian Michele Calvi |
pt_BR |
| dc.date.accessioned |
2026-01-26T12:02:24Z |
pt_BR |
| dc.date.accessioned |
2026-05-05T16:32:15Z |
|
| dc.date.available |
2026-01-26T12:02:24Z |
pt_BR |
| dc.date.available |
2026-05-05T16:32:15Z |
|
| dc.date.issued |
2025-05 |
pt_BR |
| dc.identifier.citation |
https://doi.org/10.1007/978-3-031-98893-6_26 |
pt_BR |
| dc.identifier.uri |
http://dspace2.lnec.pt:8080/jspui/handle/123456789/1019475 |
pt_BR |
| dc.identifier.uri |
http://repositorio.lnec.pt:8080/jspui/handle/123456789/1019475 |
|
| dc.description.abstract |
During the last two decades fiber-reinforced elastomeric isolators (FREIs) emerged as a promising option to reduce both the cost and weight of rubber bearings. The project ERIES-FREISUST (Fiber-Reinforced Elas-tomeric Isolators for seismic resilient structures with SUSTainable Solu-tions) aims to demonstrate the reliability of FREIs in limiting damage to structural and nonstructural components and contents. Two FREI systems were designed for a full-scale 2-story reinforced concrete (RC) infilled frame, differing in standardization and cost levels, namely a Virgin-rubber Carbon-fiber FREI (VC-FREI) and a Reclaimed-rubber Polyester-fiber FREI (RP-FREI). These isolation systems were installed in unbonded con-figuration at the base of the building and tested at the ST3D shaking table facility of Laboratorio Nacional de Engenharia Civil (LNEC), Lisbon, Por-tugal. The novel base-isolation systems demonstrated lateral stability and re-centering capability, as well as adequate vertical stiffness and load-bearing capacity under different ground motions. RP-FREIs were designed and tested up to a design displacement of 105mm corresponding to 150% shear strain. Due to recessing plates VC-FREIs were tested with higher scaling factors compared to RP-FREIs showing higher displacement capaci-ty with negligible residual. The building had no minor damage after the whole testing sequence with contents undergoing limited accelerations and displacements thus ensuring functionality even after major earthquakes. |
pt_BR |
| dc.language.iso |
eng |
pt_BR |
| dc.publisher |
Springer Cham |
pt_BR |
| dc.rights |
openAccess |
pt_BR |
| dc.subject |
Base Isolation |
pt_BR |
| dc.subject |
Unbonded Elastimeric Isolators |
pt_BR |
| dc.subject |
FREI |
pt_BR |
| dc.subject |
3D Shaking Table Tests |
pt_BR |
| dc.subject |
Non Structural Components. |
pt_BR |
| dc.title |
3D Shaking Table Tests Of A Full Scale 2-Storey Building With Fiber-Reinforced Elastomeric Isolators |
pt_BR |
| dc.type |
conferenceObject |
pt_BR |
| dc.description.volume |
Proceedings of ERIES-IW2025 |
pt_BR |
| dc.description.sector |
DE/NESDE |
pt_BR |
| dc.description.magazine |
Engineering Research Infrastructures for European Synergies |
pt_BR |
| dc.identifier.conftitle |
Proceedings of ERIES-IW2025 |
pt_BR |
| dc.contributor.peer-reviewed |
NAO |
pt_BR |
| dc.contributor.academicresearchers |
SIM |
pt_BR |
| dc.contributor.arquivo |
SIM |
pt_BR |