DSpace Repository

3D Shaking Table Tests Of A Full Scale 2-Storey Building With Fiber-Reinforced Elastomeric Isolators

Show simple item record

dc.contributor.author Losanno, D. pt_BR
dc.contributor.author Prakash, S. pt_BR
dc.contributor.author Medaglia, P. pt_BR
dc.contributor.author Parisi, F. pt_BR
dc.contributor.author Konstantinidis, D. pt_BR
dc.contributor.author Tubaldi, E. pt_BR
dc.contributor.author Ahmadi, H. pt_BR
dc.contributor.author Strauss, A. pt_BR
dc.contributor.author De Domenico, D. pt_BR
dc.contributor.author Vamvatsikos, D. pt_BR
dc.contributor.author Lachanas, C. pt_BR
dc.contributor.author Vassiliou, M. pt_BR
dc.contributor.author Ribeiro, F. pt_BR
dc.contributor.author Correia, A.A. pt_BR
dc.contributor.editor Gerard J. O’Reilly pt_BR
dc.contributor.editor Gian Michele Calvi pt_BR
dc.date.accessioned 2026-01-26T12:02:24Z pt_BR
dc.date.accessioned 2026-05-05T16:32:15Z
dc.date.available 2026-01-26T12:02:24Z pt_BR
dc.date.available 2026-05-05T16:32:15Z
dc.date.issued 2025-05 pt_BR
dc.identifier.citation https://doi.org/10.1007/978-3-031-98893-6_26 pt_BR
dc.identifier.uri http://dspace2.lnec.pt:8080/jspui/handle/123456789/1019475 pt_BR
dc.identifier.uri http://repositorio.lnec.pt:8080/jspui/handle/123456789/1019475
dc.description.abstract During the last two decades fiber-reinforced elastomeric isolators (FREIs) emerged as a promising option to reduce both the cost and weight of rubber bearings. The project ERIES-FREISUST (Fiber-Reinforced Elas-tomeric Isolators for seismic resilient structures with SUSTainable Solu-tions) aims to demonstrate the reliability of FREIs in limiting damage to structural and nonstructural components and contents. Two FREI systems were designed for a full-scale 2-story reinforced concrete (RC) infilled frame, differing in standardization and cost levels, namely a Virgin-rubber Carbon-fiber FREI (VC-FREI) and a Reclaimed-rubber Polyester-fiber FREI (RP-FREI). These isolation systems were installed in unbonded con-figuration at the base of the building and tested at the ST3D shaking table facility of Laboratorio Nacional de Engenharia Civil (LNEC), Lisbon, Por-tugal. The novel base-isolation systems demonstrated lateral stability and re-centering capability, as well as adequate vertical stiffness and load-bearing capacity under different ground motions. RP-FREIs were designed and tested up to a design displacement of 105mm corresponding to 150% shear strain. Due to recessing plates VC-FREIs were tested with higher scaling factors compared to RP-FREIs showing higher displacement capaci-ty with negligible residual. The building had no minor damage after the whole testing sequence with contents undergoing limited accelerations and displacements thus ensuring functionality even after major earthquakes. pt_BR
dc.language.iso eng pt_BR
dc.publisher Springer Cham pt_BR
dc.rights openAccess pt_BR
dc.subject Base Isolation pt_BR
dc.subject Unbonded Elastimeric Isolators pt_BR
dc.subject FREI pt_BR
dc.subject 3D Shaking Table Tests pt_BR
dc.subject Non Structural Components. pt_BR
dc.title 3D Shaking Table Tests Of A Full Scale 2-Storey Building With Fiber-Reinforced Elastomeric Isolators pt_BR
dc.type conferenceObject pt_BR
dc.description.volume Proceedings of ERIES-IW2025 pt_BR
dc.description.sector DE/NESDE pt_BR
dc.description.magazine Engineering Research Infrastructures for European Synergies pt_BR
dc.identifier.conftitle Proceedings of ERIES-IW2025 pt_BR
dc.contributor.peer-reviewed NAO pt_BR
dc.contributor.academicresearchers SIM pt_BR
dc.contributor.arquivo SIM pt_BR