dc.description.abstract Long motorway tunnels equipped with two independent unidirectional galleries are usually provided with longitudinal ventilation. This ventilation scheme, when applied to smoke control, can generate significant pressure differences between both roadway galleries, which may have an impact on the use of transverse galleries (escape routes). This paper present two-case studies where the results of measure- ments of these pressure differences taken in Mara ̃o and Gardunha tunnels allowed the assessment of relevant flow parameters, as the pressure loss coefficient of the entrance portal, the friction factor in the tunnel and the coefficient of installation of the jet fans. The assessed parameters were used in the steady-flow energy equation for a streamtube to predict the impact of pressure differences on the protection of trans- verse galleries (emergency exits) in the case of fire. The results show that the pre- dicted pressure in the fire road gallery increases upstream the location of the fire and decreases downstream that location, when taking the pressure profile of the flow without fire as a reference. The models show that predicted pressure differences between the two road galleries in case of fire may be within the interval [200 Pa; - 100 Pa] in Mara ̃o tunnel and [12 Pa; - 48 Pa] in Gardunha Tunnel, while the mea- surements in the no fire case show that they lay within the interval [29 Pa; - 50 Pa] in Mara ̃o tunnel and [- 13 Pa; - 35 Pa] in Gardunha Tunnel pt_BR
dc.language.iso eng pt_BR
dc.publisher Springer Science pt_BR
dc.rights restrictedAccess pt_BR
dc.subject Tunnels pt_BR
dc.subject Fire pt_BR
dc.subject Smoke control pt_BR
dc.subject Pressure differences pt_BR
dc.title Impact of the Pressure Differences Between Road Galeries On Tunnels Generated by the Smoke Control System pt_BR
dc.type workingPaper pt_BR
dc.identifier.localedicao online pt_BR
dc.description.pages 26p pt_BR
dc.description.sector CIC/CHEFIA pt_BR
dc.description.magazine Fire Technology 2022 pt_BR
dc.contributor.peer-reviewed SIM pt_BR
dc.contributor.academicresearchers SIM pt_BR
dc.contributor.arquivo NAO pt_BR


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account