Thermal Influence on Long-Distance Optical Measurement of Suspension Bridge Displacement

Show simple item record

dc.contributor.author Lages Martins, L. pt_BR
dc.contributor.author Rebordão, J. pt_BR
dc.contributor.author Ribeiro, A. pt_BR
dc.contributor.editor Springer Science pt_BR
dc.date.accessioned 2014-12-12T10:09:12Z pt_BR
dc.date.accessioned 2017-04-12T11:07:38Z
dc.date.available 2014-12-12T10:09:12Z pt_BR
dc.date.available 2017-04-12T11:07:38Z
dc.date.issued 2014-01 pt_BR
dc.identifier.issn 0195-928X pt_BR
dc.identifier.other DOI 10.1007/s10765-014-1607-3 pt_BR
dc.identifier.uri https://repositorio.lnec.pt/jspui/handle/123456789/1006701
dc.description.abstract This paper discusses the thermal influence on long-distance and noncontact measurement of suspension bridge three-dimensional displacement by the use of an optical system composed of a digital camera, infrared active targets, and computational support. ln this type of measurement method, the optical propagation path of light through the air can range from 250 m up to 750 m, making its measurement accuracy strongly dependent on atmospheric refraction and turbulence, phenomena that are linked to the vertical temperature gradient between the camera and targets. ln addition, the adopted measurement geometrical configuration can lead to a height difference between these two elements (camera and targets) above 50 m. The paper describes the experimental setup and procedure followed for the determination of local temperature vertical gradients in the 25th of April Bridge in Lisbon (Portugal), where an optical measurement system was applied. The obtained thermal measurements are presented and applied in the evaluation of the systematic refraction vertical deviation, based on appropriate mathematical models mentioned in the paper, and for the identification of stable or unstable observation thermal conditions related to turbulence. pt_BR
dc.language.iso eng pt_BR
dc.rights openAccess pt_BR
dc.subject Displacement pt_BR
dc.subject Optical system pt_BR
dc.subject Suspension bridge pt_BR
dc.subject Temperature pt_BR
dc.title Thermal Influence on Long-Distance Optical Measurement of Suspension Bridge Displacement pt_BR
dc.type article pt_BR
dc.description.pages 19pp pt_BR
dc.description.volume 35 pt_BR
dc.description.sector CIC/NQM pt_BR
dc.description.magazine International Journal of Thermophysics pt_BR


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account