dc.description.abstract ABSTRACT: This communication presents a set of experimental results and numerical evaluations, characterizing the air permeability and ventilation system of a “Gaioleiro” building. Regarding the high rates of air infiltration obtained, namely by old wooden windows, it was studied retrofit measures for building airtightness and ventilation system. The results presented in this article show a great potential for building thermal performance improvement, regarding only the retrofit of building airtightness (window improvement or window replacement). In this article it’s also shown the threat of getting bad ventilation after sealing the building envelope. The air permeability evaluation was determined using the fan pressurization method (EN 13829:2000). The ventilation air flow rate was evaluated with tracer gas concentration decay method (EN ISO 12569:2000). Air flow rates calculation, for current construction and retrofit measures, was carried out using numerical model (EN 15242:2007), validated with the experimental results obtained. pt_BR
dc.language.iso por pt_BR
dc.publisher LNEC pt_BR
dc.rights openAccess pt_BR
dc.subject Ventilação pt_BR
dc.subject O a i pt_BR
dc.subject Permeabilidade pt_BR
dc.subject Eficiência energética pt_BR
dc.subject Pressurização pt_BR
dc.subject Reabilitação pt_BR
dc.subject Edifício gaioleiro pt_BR
dc.subject Témica pt_BR
dc.subject Simulação pt_BR
dc.subject Ensaio pt_BR
dc.title Avaliação experimental da permeabilidade ao ar da envolvente e do sistema de ventilação. Edifício "Gaioleiro" (1880) pt_BR
dc.type conferenceObject pt_BR
dc.identifier.localedicao LNEC/DED pt_BR
dc.description.figures 2 pt_BR
dc.description.tables 7 pt_BR
dc.description.pages 8p pt_BR
dc.identifier.seminario Conferência Nacional 2011 pt_BR
dc.identifier.local Lisboa pt_BR
dc.identifier.localizacao NAICI pt_BR
dc.description.sector DED/NAICI pt_BR
dc.description.year 2011 pt_BR
dc.description.data 29 e 30 de Setembro pt_BR


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account